免费观看女子推理社,韩国女主播一区二区,美女让我桶,欧美一级黄色片视频

當(dāng)前位置:首頁-新聞中心新聞中心

通風(fēng)管道各個(gè)部分安裝規(guī)范標(biāo)準(zhǔn)你清楚嗎?

發(fā)布人:http://www.bnlfans.net   發(fā)布時(shí)間:2020-06-15 19:13:16

  通風(fēng)管道各個(gè)部分安裝規(guī)范標(biāo)準(zhǔn)你清楚嗎?今天小編來給大家詳細(xì)介紹一下通風(fēng)管道各個(gè)部分安裝規(guī)范標(biāo)準(zhǔn)。

  Do you know the installation specifications and standards of each part of the ventilation duct? Today, I will introduce the installation specifications and standards of each part of the ventilation duct in detail.

  一,風(fēng)管安裝規(guī)范標(biāo)準(zhǔn)

  1、 Code and standard for air duct installation

  1.風(fēng)管內(nèi)嚴(yán)禁其他管線穿越;

  1. It is forbidden to cross other pipelines in the air duct;

  2.輸送含有易燃、易爆氣體或安裝在易燃、易爆環(huán)境的風(fēng)管系統(tǒng)應(yīng)有良好的接地,通過生活區(qū)或其他輔助生產(chǎn)房間時(shí)必須嚴(yán)密,并不得設(shè)置接口

  2. The air duct system for conveying inflammable and explosive gas or installed in inflammable and explosive environment shall be well grounded. It must be tight when passing through the living area or other auxiliary production rooms, and no interface shall be set

  3.輸送空氣溫度高于80℃的風(fēng)管,應(yīng)按設(shè)計(jì)規(guī)定采取防護(hù)措施。

  3. Protective measures shall be taken for air pipes with air temperature higher than 80 ℃ according to design regulations.

  4.室外立管的固定拉索嚴(yán)禁拉在避雷針或避雷網(wǎng)上

  4. The fixed cable of outdoor riser shall not be pulled on the lightning rod or lightning protection net

                       濟(jì)南黑白鐵加工

  二,風(fēng)管部件安裝必須符合下列規(guī)定:

  2、 The installation of air duct components must meet the following requirements:

  1.各類風(fēng)管部件及操作機(jī)構(gòu)的安裝,應(yīng)能保證其正常的使用功能,并便于操作;

  1. The installation of various air duct components and operating mechanisms shall ensure their normal use function and be easy to operate;

  2.斜插板風(fēng)閥的安裝,閥板必須為向上拉啟;水平安裝時(shí),閥板還應(yīng)為順氣流方向插入;

  2. For the installation of inclined plug plate air valve, the valve plate must be pulled upward; for horizontal installation, the valve plate shall also be inserted along the air flow direction;

  3.止回風(fēng)閥、自動(dòng)排氣活門的安裝方向應(yīng)正確。

  3. The installation direction of check air valve and automatic exhaust valve shall be correct.

  4.防火閥、排煙閥(口)的安裝方向、位置應(yīng)正確。防火分區(qū)隔墻兩側(cè)的防火閥,距墻表面不應(yīng)大于200mm。

  4. The installation direction and position of fire damper and smoke exhaust valve (port) shall be correct. The distance between the fire damper on both sides of the partition wall of the fire compartment and the wall surface shall not be more than 200mm.

  5.手動(dòng)密閉閥安裝,閥門上標(biāo)志的箭頭方向必須與受沖擊波方向一致。

  5. For the installation of manual airtight valve, the arrow direction marked on the valve must be consistent with the direction of shock wave.

  6.風(fēng)管系統(tǒng)安裝完畢后,應(yīng)按系統(tǒng)類別進(jìn)行嚴(yán)密性檢驗(yàn),漏風(fēng)量應(yīng)符合設(shè)計(jì)與風(fēng)管必須通過工藝性的檢測(cè)或驗(yàn)證,其強(qiáng)度和嚴(yán)密性要求應(yīng)符合設(shè)計(jì)或下列規(guī)定:

  6. After the installation of the air duct system, the tightness inspection shall be carried out according to the system category. The air leakage shall meet the design and the air duct must pass the technical inspection or verification, and the strength and tightness requirements shall meet the design or the following requirements:

  ① 風(fēng)管的強(qiáng)度應(yīng)能滿足在1.5倍工作壓力下接縫處無開裂;

  ① The strength of air duct shall be able to meet the requirement that there is no crack at the joint under 1.5 times of working pressure;

  ② 矩形風(fēng)管的允許漏風(fēng)量應(yīng)符合以下規(guī)定:

  ② The allowable air leakage of rectangular air duct shall meet the following requirements:

  低壓系統(tǒng)風(fēng)管 QL≤0.1056P0.65

  Low pressure system air duct QL ≤ 0.1056p0.65

  中壓系統(tǒng)風(fēng)管 QM≤0.0352P0.65

  Medium pressure system air duct QM ≤ 0.0352p0.65

  高壓系統(tǒng)風(fēng)管 QH≤0.0117 P0.65

  High pressure system air duct QH ≤ 0.0117 p0.65

  式中 QL、QM、QH——系統(tǒng)風(fēng)管在相應(yīng)工作壓力下,單位面積風(fēng)管單位時(shí)間內(nèi)的允許漏風(fēng)量[m3/(h·m2)];

  Where QL, QM, QH -- allowable air leakage of system air duct in unit time per unit area of air duct under corresponding working pressure [m3 / (H · m2)];

  P——指風(fēng)管系統(tǒng)的工作壓力(Pa)。

  P -- working pressure of air duct system (PA).

  ③ 低壓、中壓圓形金屬風(fēng)管、復(fù)合材料風(fēng)管以及采用非法蘭形式的非金屬風(fēng)管的允許漏風(fēng)量,應(yīng)為矩形風(fēng)管規(guī)定值的50%;

  ③ The allowable air leakage of low and medium pressure circular metal air ducts, composite air ducts and non-metal air ducts in non flange form shall be 50% of the specified value of rectangular air ducts;

  ④ 磚、混凝土風(fēng)道的允許漏風(fēng)量不應(yīng)大于矩形低壓系統(tǒng)風(fēng)管規(guī)定值的1.5倍;

  ④ The allowable air leakage of brick and concrete air duct shall not be greater than 1.5 times of the specified value of rectangular low-pressure system air duct;

  ⑤ 排煙、除塵、低溫送風(fēng)系統(tǒng)按中壓系統(tǒng)風(fēng)管的規(guī)定,1~5級(jí)凈化空調(diào)系統(tǒng)按高壓系統(tǒng)風(fēng)管的規(guī)定。

  ⑤ The smoke exhaust, dust removal and low temperature air supply system shall be in accordance with the provisions of the medium pressure system air duct, and the level 1-5 purification air conditioning system shall be in accordance with the provisions of the high pressure system air duct.


上一篇:通風(fēng)管道如何防腐保溫?
下一篇:衛(wèi)生間通風(fēng)管道要如何設(shè)計(jì)呢?

網(wǎng)站首頁 關(guān)于我們 產(chǎn)品展示 新聞中心 工程案例 在線留言 聯(lián)系我們

主站蜘蛛池模板: 国产精品久久久久9999| 99视频在线| 欧美午夜伦y4480私人影院| 全球全球gogo专业摄影| 性片的生活| 欧美日韩成人在线观看| 国产人妖在线播放| 国产99视频精品免视看7| 男女做污污| 日韩福利电影网| 免费看a级毛片| 一级国产电影| 狠狠色综合网站久久久久久久| 最好2018中文免费视频| 国产乱码卡一卡2卡三卡四| 再深点灬舒服灬太大了岳| 动漫美女被爆羞羞免费| 美国式禁忌芭芭拉| 足本玉蒲团在线观看| 外出电影| 韩国午夜理伦三级2020韩| 大学生情侣在线| 无翼乌邪恶工番口番邪恶| 中文字幕不卡在线播放| 国产999| 在车子颠簸中进了老师的身体| 亚洲无限资源| 啊灬啊灬啊灬快灬深一| 美女不遮不挡的免费视频裸体| 色播在线电影| 性高湖久久久久久久久aaaaa| 在线jyzzjyzz免费视频| 免费搞基| 污动漫3d| 国产精品久久久久久久| 99在线精品免费视频| 一人上面一个吃我电影| 亚洲毛片免费观看| 精品综合久久久久久98| 再深点灬舒服了灬太大了乡村| 女博士梦莹凌晨欢爱|