山東通風管道出現(xiàn)腐蝕的原因是什么
發(fā)布人:http://www.bnlfans.net 發(fā)布時間:2019-04-11 14:28:47
山東通風管道如果其出現(xiàn)腐蝕現(xiàn)象的話,那么其原因是什么呢?其有什么危害呢?
If there is corrosion in Shandong ventilation pipeline, what is the reason? What harm does it do?
風管出現(xiàn)腐蝕現(xiàn)象,其具體的表面,一般來講主要有以下這些,為:
Generally speaking, there are the following main corrosion phenomena on the concrete surface of the duct: corrosion of the duct, corrosion of the duct, corrosion of the duct, corrosion of the duct, corrosion of the duct, corrosion of the duct, corrosion of the duct, and corrosion of the duct
表現(xiàn)一:風管表面出現(xiàn)一些缺陷問題,比如擦毛、雜物等。
Performance 1: There are some defects on the surface of the air duct, such as brushing, debris and so on.
表面二:在焊縫表面,其顏色是呈黑色的,或者是有黃斑或花斑。
Surface 2: In the weld surface, its color is black, or there are macula or spots.
表面三:風管的局部出現(xiàn)銹蝕。
Surface 3: Local corrosion of air duct.
這三種情況,其腐蝕程度是越來越嚴重,一旦出現(xiàn)該問題的話,則會降低其抗腐蝕能力,縮短其使用壽命。對于通風系統(tǒng)來講,則會降低其嚴密性,所以它的危害是不容小覷的。
In these three cases, the corrosion degree is becoming more and more serious. Once this problem occurs, it will reduce its corrosion resistance and shorten its service life. For the ventilation system, it will reduce its tightness, so its harm can not be underestimated.
風管出現(xiàn)腐蝕,其主要原因,一般有以下這些,為:
The main reasons for the corrosion of air ducts are as follows:
(1)風管所使用的板材,其下料或加工方式方法不當。
(1) The blanking or processing method of the sheet used in the air duct is inappropriate.
(2)風管在加工制造過程中,就出現(xiàn)了腐蝕現(xiàn)象,但并沒有及時進行處理。
(2) In the process of manufacture, the corrosion of air duct occurs, but it is not treated in time.
(3)風管的焊接方法沒有選擇正確,也就是焊接方法不當。
(3) The welding method of air duct has not been chosen correctly, that is, the welding method is improper.
(4)風管焊接好以后,沒有及時進行清潔和清理,就進行后續(xù)處理了。
(4) After the air duct is welded, it is not cleaned and cleaned in time, so the follow-up treatment is carried out.
山東通風管道安裝時有哪些注意事項
What matters needing attention in installation of ventilation pipes in Shandong Province
1、風管成品應(yīng)按系統(tǒng)編號碼放整齊,搬運、裝卸應(yīng)輕拿輕放,防止損壞。
1. The finished products of air duct should be placed neatly according to the system number. Handling and handling should be handled lightly to prevent damage.
2、交叉作業(yè)較多加工程,嚴禁以安裝完的風管作為支、吊、托架,不允許將其它 支、吊架焊在或掛在風管法蘭和風管支、吊架上,更不能在風管上站人。
2. There are many cross-working processes. It is strictly forbidden to use installed air ducts as supports, hangers and brackets. It is not allowed to weld or hang other branches and hangers on air duct flanges, air duct supports and hangers, let alone stand on air ducts.
a.本工程風管系統(tǒng)主要有多葉調(diào)節(jié)閥、蝶閥、防火防排煙閥等各類風閥,在安裝前應(yīng)檢查框架結(jié)構(gòu)是否牢固,調(diào)節(jié)、制動、定位等裝置應(yīng)準確靈活。
A. The main air duct systems in this project are multi-leaf regulating valves, butterfly valves, fire prevention and smoke exhaust valves and other kinds of air valves. Before installation, it is necessary to check whether the frame structure is firm, and the adjusting, braking and positioning devices should be accurate and flexible.
b.根據(jù)風管法蘭螺桂孔尺寸在風閥的法蘭上打孔。
B. Punch holes on the flange of the air valve according to the size of the air pipe flange screw.
c.風閥的安裝與風管相同,在安裝時只要把閥的法蘭與風管或設(shè)備上的法蘭對正,加上密封墊上緊螺絲,使其連接牢固及緊密即可。
C. The installation of the air valve is the same as that of the air duct. During installation, the flange of the valve should be aligned with the flange of the air duct or equipment, and the tightening screw on the sealing gasket should be added to make the connection firm and tight.
d.應(yīng)注意風閥安裝部位,使閥件的操縱位置便于操作。
D. Attention should be paid to the installation position of the air valve so as to facilitate the operation of the valve parts.
e.安裝時要注意風閥的氣流方向,不得裝反,應(yīng)按風閥外殼標注的方向安裝。
E. Attention should be paid to the airflow direction of the air valve during installation. It should not be reversed. It should be installed in the direction marked by the air valve shell.
f.防火閥是通風系統(tǒng)的裝置,要保證在火災(zāi)時起到關(guān)閉和停機的作用。防火閥有水平、垂直、左式和右式之分,定貨和安裝時應(yīng)根據(jù)設(shè)計要求進行,防火閥有水平、垂直、左式和右式之分,定貨和安裝時應(yīng)根據(jù)設(shè)計要求進行,防止弄錯。為防止防火閥易熔片脫落,易熔片應(yīng)在系統(tǒng)安裝后,系統(tǒng)試運轉(zhuǎn)之前再行安裝。
F. Fire-proof valve is the safety device of ventilation system. It is necessary to ensure that it can shut down and shut down in case of fire. Fire valves are divided into horizontal, vertical, left and right types. Order and installation should be carried out according to the design requirements. Fire valves can be divided into horizontal, vertical, left and right types. Order and installation should be carried out according to the design requirements to prevent mistakes. In order to prevent the fusible sheet from falling off, the fusible sheet should be installed after the system is installed and before the system is commissioned.
g.為了方便更換和檢查防火閥的易熔片,還應(yīng)根據(jù)設(shè)計,在靠近防火閥的風管段上設(shè)置檢查門。
G. In order to replace and inspect the fusible sheet of the fire valve conveniently, an inspection door should be set on the air duct section near the fire valve according to the design.
上一篇:山東通風管道支架在制作時要注意哪些
下一篇:通風管道在安裝時怎么減小噪音